10025A DC Blower Fan | 100mm High-Pressure Centrifugal Cooling Solution
The 10025A DC Blower Fan is a centrifugal blower designed for electronic equipment and cooling systems where airflow resistance, installation space, and environmental requirements need to be considered.
With an outer dimension of Φ100.5 × 25.0 mm, the 10025A combines an aluminum alloy frame, an engineering plastic impeller, and dual ball bearings. The listed 24V configuration operates at 5500 RPM and delivers 85.1 m³/h airflow with a static pressure of 335.7 Pa.
The series also provides selectable voltage and signal options, together with environmental configurations for ground, marine, and airborne applications.
Key Structural Features
- Dimensions: Φ100.5 × 25.0 mm
- Frame Material: Aluminum alloy
- Impeller Material: Engineering plastic
- Bearing System: Dual ball bearings
- Weight: 180 g
The aluminum alloy frame and engineering plastic impeller provide a combination of metal and polymer components in a compact centrifugal blower structure.
Performance Specifications
The product page currently lists the following detailed performance configuration:
| Model | Voltage | Operating Voltage Range | Speed | Airflow | Static Pressure | Noise | Power |
|---|---|---|---|---|---|---|---|
| J100FLW355-25A00 | 24V | 18.0–32.0V | 5500 RPM | 85.1 m³/h | 335.7 Pa | 57.4 dBA | 9.8 W |
Available Voltage Options
The product page lists 5V, 12V, 24V, 28V, and 48V as available voltage options.
Detailed performance data are currently listed for the 24V configuration above. Performance specifications for other voltage options should be confirmed separately according to the required operating conditions.
When selecting the blower, engineers should consider the required airflow, system resistance, available electrical power, installation dimensions, and acceptable noise level. Actual operating performance depends on the complete airflow system and its operating point.
Optional Signal Functions
The 10025A series supports several signal configurations for equipment control and monitoring.
Available options include:
- No Signal Function
- PWM Duty Cycle Speed Control
- High-Level Fault Alarm
- Tachometer (RPM) Feedback
- PWM Control + High-Level Fault Alarm
- PWM Control + Tachometer Feedback
The model suffix identifies the selected signal function and environmental rating. For example, A00 indicates signal function code 0 (No Function) and environmental rating code 0 (Ground / Vehicle-Mounted).
The required signal configuration should be specified when requesting a quotation or customized version.
Environmental Adaptability
The 10025A DC Blower Fan provides selectable environmental configurations for three application categories:
- Ground / Vehicle-Mounted
- Marine / Naval
- Airborne
The product environmental table lists testing items including:
- High-temperature and low-temperature exposure
- Rain exposure
- Damp heat and humidity
- Fungus resistance
- Neutral or acidic salt spray, depending on the selected environmental rating
- Blowing sand and dust
- Acceleration and mechanical shock
- Low air pressure and acidic atmosphere for the airborne configuration
- EMC requirements
Some listed environmental conditions vary by configuration.
For Ground / Vehicle-Mounted applications, the table specifies high-temperature storage at 80°C and operation at 75°C, low-temperature storage at -50°C and operation at -40°C, and a 20g mechanical shock test.
For Marine / Naval applications, the listed temperature levels are 95°C for storage and 85°C for operation at high temperature, and -60°C for storage and -55°C for operation at low temperature. The table also specifies acidic salt spray for 192 hours and a 30g mechanical shock test.
For Airborne applications, the table lists a low-pressure test at 6.3 kPa, an acidic-atmosphere test, and an abnormal overvoltage condition of 50V for 50ms.
The product page lists RE102 and CE102 under EMC requirements. The vibration standard GJB150.16A-2009 is also listed, but no specific vibration test level is provided in the current table.
The appropriate environmental rating should be selected according to the intended installation conditions and project requirements. These configurations should not be interpreted as applying to every standard model.
Typical Applications
The 10025A DC Blower Fan can be considered for cooling systems in applications such as:
- Industrial control cabinets
- Power electronics and converters
- Communication and networking equipment
- High-resistance air duct cooling
- Ground and vehicle-mounted electronic systems
- Marine and naval electronic equipment
- Airborne electronic equipment with the appropriate environmental configuration
Final selection should be based on the required airflow, system resistance, operating voltage, installation dimensions, signal functions, and environmental conditions.
OEM / ODM Customization
SenharFans supports OEM and ODM customization options, subject to technical evaluation. Available options may include:
- Operating voltage configurations
- Signal and control functions
- Performance requirements
- Environmental adaptability ratings
For product selection or technical evaluation, please share your application details, required voltage, and operating conditions with our team.
Contact SenharFans
Email: sales@senharfans.com
Phone / WhatsApp: +86-138-1239-0890
Website: https://senharfans.com/