12025A DC Axial Flow Fan – 120×120×25mm High-Airflow Cooling Fan for Industrial Electronics
The SenharFans 12025A DC Axial Flow Fan is a 120×120×25mm cooling fan designed for industrial electronic equipment, control cabinets, power systems, communication devices, and enclosure ventilation applications.
With a maximum rated airflow of 312.9 m³/h across its listed speed configurations, the 12025A combines a standard 120mm mounting footprint with a slim 25mm profile. It is available in 4,000 RPM, 4,500 RPM, and 5,000 RPM configurations, allowing equipment designers to evaluate airflow, static pressure, power consumption, and noise according to their cooling requirements.
Featuring an engineering plastic frame and impeller, dual ball bearings, and configurable signal functions, the 12025A DC axial fan offers flexible integration options for industrial and electronic thermal management systems.
1. Product Overview and Structural Design
The 12025A is designed for equipment requiring a relatively large fan mounting area while maintaining a limited installation depth.
Its 120×120mm footprint provides a larger airflow area than smaller fan formats, while the 25mm thickness supports installation in equipment where available space is restricted.
Mechanical Specifications
| Parameter | Specification |
|---|---|
| Model | 12025A DC Axial Flow Fan |
| Dimensions | 120 × 120 × 25 mm |
| Frame Material | Engineering Plastic |
| Impeller Material | Engineering Plastic |
| Bearing Structure | Dual Ball Bearings |
| Weight | 200 g |
The dual ball bearing structure is suitable for the fan’s specified operating configurations. The final selection should consider the installation orientation, operating temperature, duty cycle, and application requirements.

2. Airflow and Static Pressure Performance
The 12025A series offers three primary rotational speed configurations.
Performance Specifications
| Speed | Airflow | Static Pressure | Power | Noise |
|---|---|---|---|---|
| 4,000 RPM | 248.1 m³/h | 131 Pa | 10.1 W | 57.2 dBA |
| 4,500 RPM | 280.3 m³/h | 166 Pa | 14.4 W | 59.2 dBA |
| 5,000 RPM | 312.9 m³/h | 209 Pa | 19.2 W | 61.8 dBA |
The 5,000 RPM configuration provides the highest rated airflow and static pressure among the listed configurations, with airflow reaching 312.9 m³/h and static pressure reaching 209 Pa.
The three speed options allow engineers to compare different cooling performance levels and power requirements during preliminary system design.
Selecting the Appropriate Speed
4,000 RPM
The lowest-speed configuration offers the lowest listed power consumption and noise level. It may be suitable for applications where the required cooling airflow can be achieved without using the higher-speed versions.
4,500 RPM
The mid-speed configuration provides higher airflow and static pressure than the 4,000 RPM version. It can be evaluated for equipment with moderately higher cooling requirements.
5,000 RPM
The highest-speed configuration provides the greatest rated airflow and static pressure among the listed versions. It may be considered for systems requiring greater airflow capacity, subject to the system resistance and acceptable noise and power consumption.
The actual airflow after installation depends on the system operating point. Engineers should review the fan performance curve and account for resistance from filters, grilles, heat exchangers, ducts, and internal equipment structures.

3. Voltage Options and Electrical Compatibility
The 12025A DC axial fan is available in multiple voltage configurations for different equipment power systems.
Available Voltage Options
| Rated Voltage | Operating Voltage Range |
|---|---|
| 12V | 8.0–13.8V |
| 24V | 16.0–27.6V |
| 28V | 18.0–32.0V |
| 5V | Optional |
| 48V | Optional |
Detailed performance data are listed for the 12V, 24V, and 28V configurations.
The 24V version can be considered for industrial control systems, power equipment, communication cabinets, and other equipment designed around nominal 24V power supplies.
The 28V version is available for equipment designed around nominal 28V power systems.
The 5V and 48V configurations are optional. Their detailed performance parameters should be confirmed according to the selected model and electrical configuration.
4. Intelligent Signal Functions
The 12025A series supports several signal options for integration with equipment monitoring and thermal control systems.
Signal Configuration Options
| Code | Signal Function |
|---|---|
| 0 | No Function |
| 1 | PWM Duty Cycle Speed Control |
| 2 | High-Level Fault Alarm |
| 3 | Tachometer (RPM Feedback) |
| 4 | PWM Speed Control + High-Level Fault Alarm |
| 5 | PWM Speed Control + Tachometer Feedback |
PWM speed control allows the fan to operate with a compatible control system for adjustable cooling.
Tachometer feedback provides rotational speed information for system monitoring, while the fault alarm option can support equipment-level fault detection.
The appropriate signal configuration should be selected according to the equipment’s electrical interface and control requirements.
5. Environmental Performance and Configuration Options
The 12025A series provides environmental performance configurations for ground/vehicle-mounted and marine/naval applications.
The product specifications reference environmental test standards including:
- High Temperature: GJB150.3A-2009
- Low Temperature: GJB150.4A-2009
- Rain: GJB150.8A-2009
- Damp Heat: GJB150.9A-2009
- Fungus: GJB150.10A-2009
- Salt Spray: GJB150.11A-2009
- Sand and Dust: GJB150.12A-2009
- Acceleration: GJB150.15A-2009
- Shock: GJB150.18A-2009
- Vibration: GJB150.16A-2009
Ground / Vehicle Environmental Ratings
| Test | Specification |
|---|---|
| Storage High Temperature | 80°C |
| Operating High Temperature | 75°C |
| Storage Low Temperature | −50°C |
| Operating Low Temperature | −40°C |
| Neutral Salt Spray | 192 hours |
| Rain / Water Ingress | Enhanced, 1 hour per surface |
| Cyclic Humidity | 30°C–60°C, RH 95%±5%, 24h per cycle, 10 cycles |
| Fungus Resistance | Group 1 or Group 2, 28 days |
| Acceleration Performance Test | 9g |
| Structural Acceleration Test | 13.5g |
| Shock | Three-axis, six-direction, 18 shocks total, 20g |
Marine / Naval Configuration
The marine configuration includes acidic salt spray testing for 192 hours.
The product specifications also provide environmental test options and configurations for applications requiring marine environmental evaluation.
The applicable temperature, salt spray, and other environmental requirements should be confirmed according to the selected configuration and project specifications.
Environmental performance should be evaluated based on the actual application, mounting arrangement, and required qualification conditions.

6. Application Areas
The 12025A DC axial fan can be considered for equipment requiring a 120mm fan mounting footprint, relatively high airflow, and a slim installation profile.
Industrial Control Cabinets
Control cabinets often contain power supplies, drives, control modules, relays, and other heat-generating components.
The 12025A can be evaluated for cabinet ventilation and forced-air cooling where the mounting space accommodates a 120×120×25mm fan.
The required airflow should be determined according to heat dissipation, cabinet ventilation design, and system resistance.
Power Supply and Electrical Equipment
Power electronics and electrical equipment may require forced-air cooling to maintain suitable operating temperatures.
The 12025A offers multiple speed configurations for evaluating cooling performance according to the equipment’s heat load and airflow path.
Communication Equipment
Communication cabinets, network equipment, and electronic enclosures may use axial fans to move air through internal components and ventilation openings.
The 120mm mounting footprint provides an option for equipment designers who require a larger fan format within a limited installation depth.
Outdoor Electronic Enclosures
Outdoor enclosures may require ventilation to manage internal heat accumulation.
The fan selection should consider the complete enclosure design, protective grilles, filters, ingress protection requirements, and the intended environmental configuration.
Vehicle-Mounted Electronics
The 12025A can be considered for vehicle-mounted control equipment, communication systems, and electronic enclosures requiring forced-air cooling.
The ground/vehicle environmental configuration should be evaluated according to the project’s temperature, shock, acceleration, and installation requirements.
7. Why Choose the SenharFans 12025A?
- 120×120×25mm standard mounting dimensions
- Maximum rated airflow of 312.9 m³/h
- Static pressure up to 209 Pa
- Three primary speed configurations: 4,000 / 4,500 / 5,000 RPM
- 12V, 24V, and 28V detailed performance configurations
- Additional 5V and 48V voltage options
- Engineering plastic frame and impeller
- Dual ball bearing structure
- Configurable PWM, fault alarm, and tachometer signal functions
- Ground/vehicle and marine environmental configurations
The 12025A provides multiple airflow and electrical configuration options for industrial equipment designers seeking a 120mm axial fan with a slim 25mm installation profile.
8. Technical Support and Custom Configuration
Choosing a cooling fan requires evaluating the equipment’s complete thermal and mechanical requirements.
Airflow, system pressure, installation dimensions, rated voltage, signal functions, noise constraints, operating temperature, and environmental conditions should all be considered during the selection process.
SenharFans provides DC axial fans, AC axial fans, and DC blower fans for industrial and electronic thermal management applications.
For the 12025A series, our engineering team can assist with fan selection, performance curves, technical documentation, and configuration requirements.
Contact SenharFans