Request Custom Quote

5020A DC Blower Fan | Compact 50mm High-Pressure Cooling

SenharFans
5020A DC Blower Fan | Compact 50mm High-Pressure Cooling

5020A DC Blower Fan | Compact 50mm High-Pressure Cooling

The SenharFans 5020A DC Blower Fan is a compact centrifugal cooling fan measuring 50.4 × 50.4 × 20.0 mm. Designed for electronic equipment and assemblies with limited installation space, it combines an engineering-plastic frame and impeller with dual ball bearings.

With three documented speed configurations, the 5020A provides airflow from 7.8 to 11.5 m³/h and static pressure from 53.9 to 120.6 Pa, giving equipment designers flexibility when selecting a cooling solution for systems with different airflow resistance requirements.

Compact Centrifugal Design

The 5020A uses a centrifugal impeller to direct airflow through its outlet. This design is suitable for compact equipment where airflow needs to follow a defined path or pass through internal components, ducts, or other airflow restrictions.

Key structural specifications:

  • Model: 5020A DC Blower Fan
  • Dimensions: 50.4 × 50.4 × 20.0 mm
  • Frame material: Engineering plastic
  • Impeller material: Engineering plastic
  • Bearing system: Dual ball bearings
  • Weight: 35.0 g

Electrical and Airflow Performance

The 5020A series has documented performance configurations for 12V, 24V, and 28V power systems. Each voltage version offers three speed options.

Rated Voltage Speed (RPM) Airflow (m³/h) Static Pressure (Pa) Noise (dBA) Power (W)
12V / 24V / 28V 4,000 7.8 53.9 30.5 1.1
12V / 24V / 28V 5,000 9.7 84.3 32.0 1.3
12V / 24V / 28V 6,000 11.5 120.6 36.0 1.7

The operating voltage ranges are:

  • 12V version: 8.0–13.8V
  • 24V version: 16.0–27.6V
  • 28V version: 18.0–32.0V

Additional voltage options, including 5V and 48V, are available upon request. Detailed performance data for these options should be confirmed separately.

The listed airflow, static pressure, and noise values correspond to different speed configurations. Maximum airflow and maximum static pressure should not be interpreted as occurring simultaneously. Actual operating performance depends on system resistance and the selected fan operating point.

[Insert mechanical dimension drawing]

[Insert airflow performance curve]

Signal and Control Options

The 5020A series offers optional signal configurations for different system integration requirements.

Available signal functions include:

  • Code 0: No signal function
  • Code 1: PWM duty-cycle speed control
  • Code 2: High-level fault alarm
  • Code 3: Tachometer (RPM) feedback
  • Code 4: PWM speed control + high-level fault alarm
  • Code 5: PWM speed control + tachometer feedback

The models listed in the standard performance table end in A00, indicating signal code 0. Other signal configurations can be discussed according to the control and monitoring requirements of the application.

Environmental Adaptability

The 5020A series provides two environmental adaptability configurations:

  • Code 0: Ground / Vehicle-Mounted
  • Code 1: Marine / Naval

The environmental test specifications listed for the series cover temperature exposure, rain, damp heat, fungus, salt spray, blowing sand and dust, acceleration, and mechanical shock.

For the documented Ground / Vehicle-Mounted configuration, the published conditions include:

  • High temperature: 80°C storage, 75°C operation
  • Low temperature: –50°C storage, –40°C operation
  • Rain: Enhanced exposure, 1 hour per surface
  • Damp heat: 30°C–60°C, RH 95% ±5%, 10 cycles
  • Fungus resistance: Group 1 or Group 2, 28 days
  • Neutral salt spray: 192 hours
  • Acceleration: 9g performance test, 13.5g structural test
  • Shock: 20g, three-axis and six-direction testing

The Marine / Naval configuration specifies acidic salt spray for 192 hours.

The published product table does not specify qualification levels for low air pressure, acidic atmosphere, EMC, or power supply characteristics. A vibration test standard is listed, but no test level is provided. These items should be confirmed separately if they are required by the project.

Environmental suitability should be evaluated against the exact model configuration and the operating conditions of the equipment.

Typical Applications

The 5020A DC blower fan can be considered for cooling requirements in:

  • Power electronics and converter assemblies
  • Industrial control equipment
  • Communication equipment
  • Radar and electronic subsystems
  • Vehicle-mounted electronic equipment
  • Selected marine electronic systems with the appropriate environmental configuration

Final selection should take into account installation dimensions, airflow path, system impedance, operating voltage, noise requirements, and environmental conditions.

OEM and Customization Support

SenharFans supports OEM/ODM requirements for DC blower fan applications. Depending on project needs, customers can discuss voltage options, speed configurations, signal functions, and environmental adaptability ratings.

For technical details, model selection, or a quotation, please contact:

SenharFans
Email: sales@senharfans.com
Tel / WhatsApp: +86-138-1239-0890

Contact our team with your operating conditions and installation requirements to discuss a suitable 5020A configuration.

Share This Article