Request Custom Quote

8041B DC Axial Fan: Aluminum Alloy Cooling for Demanding Applications

SenharFans
8041B DC Axial Fan: Aluminum Alloy Cooling for Demanding Applications

8041B DC Axial Fan: Aluminum Alloy Cooling for Demanding Applications

The 8041B DC axial fan is designed for electronic equipment and industrial systems that require substantial airflow, high static pressure, and an aluminum alloy construction. With a diameter of 82.5 mm and a depth of 41.0 mm, this fan combines an aluminum alloy frame and impeller with a dual ball bearing structure.

The 8041B series offers two listed performance configurations, reaching speeds of up to 22,000 RPM, airflow of up to 197.9 m³/h, and static pressure of up to 783.0 Pa. These characteristics make it a candidate for evaluating cooling solutions in radar equipment, communication systems, vehicle-mounted electronics, marine equipment, and other applications where airflow resistance and environmental requirements are important design considerations.


1. Key Features of the 8041B DC Axial Fan

Aluminum Alloy Frame and Impeller

The 8041B uses aluminum alloy for both its frame and impeller. This metal construction provides a rigid fan structure for equipment integration.

When evaluating an aluminum alloy cooling fan, engineers should consider the mechanical properties required by the application, the mounting arrangement, operating temperature, vibration exposure, and the overall equipment design.

The suitability of the fan should be assessed against the complete system’s requirements rather than material selection alone.

Dual Ball Bearing Structure

The 8041B features dual ball bearings. Bearing configuration is an important factor when selecting a fan for equipment that operates for extended periods or experiences demanding environmental conditions.

Actual service life depends on the selected configuration, operating temperature, vibration, mounting conditions, and electrical loading. Consult the relevant product documentation when a defined service-life requirement applies.

High Airflow and Static Pressure

The 8041B series includes two listed performance configurations:

  • 8,000 RPM: airflow of 102.9 m³/h and static pressure of 184.4 Pa
  • 22,000 RPM: airflow of 197.9 m³/h and static pressure of 783.0 Pa

The higher-speed configuration provides greater listed airflow and static pressure, but it also has higher power consumption and noise.

These maximum values should be considered alongside the fan performance curve. Actual airflow depends on the resistance of the installed system, so engineers should evaluate the operating point under the intended installation conditions.

 

 

 

2. 8041B DC Axial Fan Specifications

Parameter Specification
Fan dimensions Φ82.5 × 41.0 mm
Frame material Aluminum alloy
Impeller material Aluminum alloy
Bearing structure Dual ball bearings
Weight 188 g
Rated voltage for listed performance data 28V DC
Operating voltage range 18.0–32.0V
Additional voltage options 5V, 12V, 24V, 48V; confirm model-specific performance
Maximum listed speed 22,000 RPM
Maximum listed airflow 197.9 m³/h
Maximum listed static pressure 783.0 Pa
Listed noise range 52.5–77.2 dBA

Performance Data by Model

Model Number Rated Voltage Operating Voltage Power Speed Airflow Static Pressure Noise
J80FZW380-41B00 28V 18.0–32.0V 19.6 W 8,000 RPM 102.9 m³/h 184.4 Pa 52.5 dBA
J80FZW3K2-41B00 28V 18.0–32.0V 36.4 W 22,000 RPM 197.9 m³/h 783.0 Pa 77.2 dBA

The product page also lists 5V, 12V, 24V, and 48V as available voltage options. Performance specifications for those versions should be confirmed separately before selection.

Product image: Mechanical dimensions

3. Signal and Control Functions

The 8041B series supports several signal-function options that can be selected according to system-control and monitoring requirements.

Function Code Description
0 No signal function
1 PWM duty-cycle speed control
2 High-level fault alarm
3 Tachometer (RPM) feedback
4 PWM speed control + high-level fault alarm
5 PWM speed control + tachometer feedback

PWM speed control allows the fan speed to be adjusted through a compatible control interface. Tachometer feedback provides rotational-speed information for system monitoring, while a fault-alarm output can support equipment diagnostics.

The required signal function should be specified when ordering. Confirm the electrical interface, signal definition, connector, and cable arrangement for the selected model.

 

4. Environmental Adaptability and Testing

The 8041B product page lists environmental adaptability options for ground or vehicle-mounted equipment, marine or naval applications, and airborne applications. It also references GJB environmental and electrical test standards.

The listed test categories include:

  • High- and low-temperature exposure
  • Rain and water exposure
  • Damp heat and humidity
  • Fungus resistance
  • Neutral and acidic salt spray
  • Sand and dust
  • Acceleration and shock
  • Low air pressure for applicable ratings
  • Acidic atmosphere for applicable ratings
  • Electromagnetic compatibility
  • Power-supply characteristics and abnormal overvoltage
  • Vibration

Temperature Conditions

The product page lists the following operating-temperature limits by environmental category:

Environmental Category High-Temperature Operation Low-Temperature Operation
Ground / vehicle-mounted 75°C −40°C
Marine / naval 85°C −55°C
Airborne 85°C −55°C

Storage-temperature limits differ from operating-temperature limits. Confirm both when specifying the fan for equipment exposed to extreme temperatures during transport or storage.

Salt Spray, Shock, and Vibration

The product page lists neutral salt spray testing for 192 hours and acidic salt spray testing for 192 hours under the applicable environmental rating.

The listed shock conditions differ by rating:

  • Ground / vehicle-mounted: 20g
  • Marine / naval and airborne: 40g

The product page also references GJB151B-2013 electromagnetic compatibility requirements, including RE102 and CE102, and GJB181B-2012 power-supply characteristics, including an abnormal overvoltage condition of 80V for 50 ms under the applicable rating.

These values should not be interpreted as universal ratings for every 8041B configuration. For projects with specific qualification requirements, confirm the selected model code, applicable environmental category, test conditions, and supporting documentation with SenharFans.

 

5. Typical Applications

The 8041B DC axial fan can be evaluated for systems that require forced-air cooling and an aluminum alloy fan structure.

Military and Defense Electronics

Electronic equipment used in demanding environments may require a carefully engineered cooling solution that accounts for heat generation, restricted airflow paths, vibration, and electrical requirements.

The 8041B’s performance options and environmental-rating choices provide starting points for evaluating its suitability for these applications.

Vehicle-Mounted and Ground Systems

Vehicle-mounted electronics and mobile equipment can experience vibration, shock, and changing ambient temperatures. Fan selection should account for the mounting arrangement, enclosure resistance, operating temperature, and applicable environmental qualification.

Marine and Naval Electronics

Marine installations may involve humidity, salt exposure, vibration, and temperature variations. Confirm that the selected environmental rating and supporting test documentation match the intended shipboard application.

Airborne Electronic Equipment

Airborne systems may impose requirements for operating temperature, vibration, shock, low air pressure, and electrical compatibility. The applicable qualification level should be confirmed before integrating the fan into an airborne platform.

Radar and Communication Systems

Radar and communication equipment may contain concentrated heat sources and restricted internal airflow paths. The 8041B’s listed airflow and static-pressure characteristics can be evaluated against the system’s cooling requirements.

Industrial Control and Power Electronics

Industrial control equipment and power electronics may require forced-air cooling to manage component temperatures. Engineers should assess airflow resistance, power consumption, noise, and installation space when comparing fan configurations.

6. How to Select the Right 8041B Configuration

Before integrating the 8041B into an equipment design, review the following factors.

1. Determine the cooling requirement.
Estimate the heat generated by the components and calculate the airflow required to maintain acceptable operating temperatures.

2. Evaluate system resistance.
Filters, heat sinks, ducts, grilles, and other restrictions affect the fan’s operating point. Use the performance curve to estimate the airflow available under the actual installation conditions.

3. Select the appropriate voltage.
The listed performance configurations are rated at 28V DC, with an operating range of 18.0–32.0V. Confirm the performance data for any other voltage option before final selection.

4. Choose the required control functions.
Determine whether the system needs PWM speed control, tachometer feedback, a fault-alarm output, or a combination of functions.

5. Confirm the environmental rating.
Identify whether the application requires ground/vehicle-mounted, marine/naval, or airborne adaptability. Verify the corresponding test requirements and documentation.

6. Review power and noise constraints.
The listed configurations consume 19.6 W and 36.4 W, with noise ratings of 52.5 dBA and 77.2 dBA, respectively. Consider the equipment’s power budget, acoustic limits, and cooling objectives when choosing between them.

7. Request Technical Support for the 8041B DC Axial Fan

SenharFans supplies DC axial fans for industrial and specialized electronic cooling applications. The 8041B series provides aluminum alloy construction, multiple performance configurations, and optional signal functions for equipment manufacturers and system integrators.

To help identify a suitable configuration, please provide:

  • Required rated voltage
  • Target airflow and estimated system resistance
  • Available installation space
  • Operating temperature and environmental conditions
  • Required PWM, tachometer, or fault-alarm functions
  • Applicable qualification or test requirements
  • Estimated order quantity

The SenharFans team can review your application requirements and help determine which configuration should be evaluated for your system.

Contact: sales@senharfans.com
Product page: 8041B DC Axial Flow Fan

For detailed dimensions, performance curves, electrical interfaces, and environmental qualification information, consult the product documentation and confirm model-specific requirements before final integration.