Request Custom Quote

14038A DC Axial Fan: High-Airflow Cooling for Large Electronic Systems

SenharFans
14038A DC Axial Fan: High-Airflow Cooling for Large Electronic Systems

14038A DC Axial Fan: High-Airflow Cooling for Large Electronic Systems

The 14038A DC Axial Fan is a 140 × 140 × 38 mm cooling solution designed for large electronic enclosures and equipment that require substantial airflow and static pressure.

Featuring an engineering plastic frame and impeller, dual ball bearings, and multiple speed configurations, the 14038A series offers different performance options for industrial electronics, power equipment, communication systems, and specialized electronic applications.

With available 12V, 24V, and 28V performance configurations, engineers can select a suitable model according to the system’s power supply, airflow requirements, and airflow resistance.


1. Structural Design and Specifications

The 14038A DC axial fan combines a large airflow area with a compact 38 mm profile.

Parameter Specification
Model Series 14038A
Dimensions 140 × 140 × 38 mm
Frame Material Engineering Plastic
Impeller Material Engineering Plastic
Bearing System Dual Ball Bearings
Weight 550 g

The dual ball bearing structure supports continuous fan operation. The engineering plastic frame and impeller provide a lightweight structural design for integration into electronic equipment.

2. Performance Specifications

The 14038A series includes multiple speed and performance configurations. The following table summarizes the detailed performance data published for the 12V, 24V, and 28V models.

Rated Voltage Speed (RPM) Airflow (m³/h) Static Pressure (Pa) Noise (dBA) Power (W)
12V 2,600 161.9 67.6 44.6 9.0
12V 5,000 311.4 250.2 58.8 21.0
12V 6,500 404.8 481.0 65.8 30.9
24V 2,600 161.9 67.6 44.6 9.0
24V 5,000 311.4 250.2 58.8 21.0
24V 7,500 467.1 640.4 69.0 47.5
28V 2,600 161.9 67.6 44.6 9.0
28V 5,000 311.4 250.2 58.8 21.0
28V 7,500 467.1 640.4 69.0 47.5

Available voltage options: 5V, 12V, 24V, 28V, and 48V. Detailed performance data listed above is available for the specified 12V, 24V, and 28V configurations. Please contact SenharFans to confirm performance data for other voltage requirements.

Understanding Airflow and Static Pressure

The 14038A series reaches a maximum listed airflow of 467.1 m³/h and a maximum listed static pressure of 640.4 Pa.

These figures represent different performance limits on the fan curve. Actual airflow depends on the resistance of the installed system, including air ducts, filters, heat exchangers, and enclosure openings.

Engineers should therefore evaluate the fan’s performance curve against the system resistance curve rather than selecting a fan based only on its maximum airflow or maximum static pressure.

3. Signal and Speed Control Options

The 14038A series supports several optional signal configurations for system control and monitoring.

Signal Code Function
0 No signal function
1 PWM duty-cycle speed control
2 High-level fault alarm
3 Tachometer (RPM) feedback
4 PWM control + high-level fault alarm
5 PWM control + tachometer feedback

These options allow equipment designers to select the control and monitoring functions required by their thermal management systems.

The signal configuration should be confirmed when placing an order, as it depends on the selected model.

 

4. Environmental Adaptability

The 14038A series offers environmental adaptability options for ground/vehicle-mounted, marine/naval, and airborne applications.

The product’s published environmental test requirements cover several conditions under GJB military environmental standards.

Test Category Standard Published Test Requirements
High Temperature GJB150.3A-2009 Ground/vehicle: 80°C storage, 75°C operation; marine/airborne: 95°C storage, 85°C operation
Low Temperature GJB150.4A-2009 Ground/vehicle: -50°C storage, -40°C operation; marine/airborne: -60°C storage, -55°C operation
Rain / Water Ingress GJB150.8A-2009 Enhanced test, 1 hour per surface
Damp Heat GJB150.9A-2009 30°C–60°C, RH 95% ±5%, 24 hours per cycle, 10 cycles
Fungus Resistance GJB150.10A-2009 Fungus group 1 or 2, 28 days
Salt Spray GJB150.11A-2009 Neutral salt spray, 192 hours for ground/marine; acidic salt spray, 192 hours for airborne
Sand and Dust GJB150.12A-2009 Blowing sand and dust test
Acceleration GJB150.15A-2009 9g performance test; 13.5g structural test
Shock GJB150.18A-2009 20g for ground/vehicle; 30g for marine/airborne
Low Air Pressure GJB150.2A-2009 6.3 kPa for airborne applications
Acidic Atmosphere GJB150.28A-2009 Airborne: 2-hour spray + 22-hour storage per cycle, 3 cycles
EMC GJB151B-2013 RE102 and CE102
Power Supply Characteristics GJB181B-2012 Airborne abnormal overvoltage: 50V / 50ms
Vibration GJB150.16A-2009 Vibration testing

The environmental requirements vary according to the selected rating. Not every configuration necessarily includes every environmental qualification. Please confirm the required environmental category and test documentation when specifying the fan.

 

5. Typical Applications

The 14038A DC axial fan can be considered for equipment requiring a relatively large airflow capacity and a suitable static pressure operating point.

Typical application areas include:

  • Power Electronics: Cooling for power conversion equipment, inverters, and high-power electronic assemblies.
  • Communication Systems: Thermal management for communication equipment and electronic enclosures.
  • Radar and Electronic Systems: Cooling for radar subsystems and signal-processing equipment.
  • Industrial Control: Ventilation and heat dissipation in industrial control cabinets and automation equipment.
  • Vehicle-Mounted Equipment: Cooling for electronic systems installed in specialized vehicles.
  • Marine and Airborne Equipment: Configurations selected according to the required environmental rating.

Final suitability depends on the system’s thermal load, installation conditions, electrical requirements, and environmental qualification needs.

6. How to Select the Right 14038A Configuration

Before selecting a 14038A model, equipment manufacturers and system integrators should consider:

  1. Power Supply: Confirm whether the system uses 12V, 24V, or 28V. Other voltage options should be discussed with the manufacturer.
  2. Airflow Requirement: Estimate the airflow needed to remove heat from the equipment.
  3. System Resistance: Consider filters, ducts, grilles, and other restrictions that affect actual airflow.
  4. Control Requirements: Determine whether PWM speed control, tachometer feedback, or fault alarm functions are needed.
  5. Environmental Conditions: Select the appropriate ground/vehicle, marine/naval, or airborne environmental rating.

For customized equipment projects, sharing the operating voltage, installation dimensions, target airflow, system resistance, and environmental requirements will help identify a suitable configuration.

7. Contact SenharFans

SenharFans provides DC axial fans and customized cooling solutions for industrial electronics and specialized equipment applications.

If you are evaluating the 14038A DC axial fan for your project, contact our team for detailed specifications, performance curves, and configuration support.

Email: sales@senharfans.com
Phone / WhatsApp: +86-138-1239-0890
Website: https://senharfans.com/

Contact SenharFans to discuss your cooling requirements and find a suitable fan configuration for your equipment.

Share This Article