4028B DC Axial Fan: High Static Pressure Cooling for Compact Electronic Systems
Product Overview
The SenharFans 4028B DC Axial Fan is designed for electronic equipment that requires high airflow and static pressure within a compact installation space. Measuring 40.0 × 40.0 × 28.0 mm, the 4028B series offers multiple speed and voltage configurations for different cooling requirements.
With nominal speeds ranging from 13,000 to 25,000 RPM and listed static pressure reaching 750 Pa, the series provides options for systems where airflow resistance is an important consideration.
Potential applications include industrial electronics, communication equipment, radar-related systems, and vehicle-mounted electronics. The appropriate configuration depends on the required operating point, noise limits, electrical interface, and environmental conditions of the finished equipment.

Key Features
- Dimensions: 40.0 × 40.0 × 28.0 mm
- Frame material: Engineering plastic
- Impeller material: Engineering plastic
- Bearing type: Dual ball bearings
- Weight: Approximately 54.0 g
- Rated voltage options: 12 V, 24 V, and 28 V
- Speed options: 13,000, 18,000, and 25,000 RPM
- Maximum listed airflow: 47.5 m³/h
- Maximum listed static pressure: 750 Pa
- Optional signal functions: PWM speed control, tachometer feedback, and fault alarm, depending on configuration
The combination of a compact frame and several performance levels allows engineers to evaluate different cooling configurations without changing the nominal fan dimensions.
4028B DC Axial Fan Specifications
The following table summarizes the supplied performance data for the 4028B series.
| Model | Rated Voltage | Operating Voltage | Power | Speed | Airflow | Static Pressure | Noise |
|---|---|---|---|---|---|---|---|
| J40FZW1J3-28B00 | 12 V | 8.0–13.8 V | 3.2 W | 13,000 RPM | 26.8 m³/h | 236.5 Pa | 49.5 dBA |
| J40FZW1J8-28B00 | 12 V | 8.0–13.8 V | 5.8 W | 18,000 RPM | 34.7 m³/h | 412.0 Pa | 56.6 dBA |
| J40FZW1K5-28B00 | 12 V | 8.0–13.8 V | 13.3 W | 25,000 RPM | 47.5 m³/h | 750.0 Pa | 63.7 dBA |
| J40FZW2J3-28B00 | 24 V | 16.0–27.6 V | 3.2 W | 13,000 RPM | 26.8 m³/h | 236.5 Pa | 49.5 dBA |
| J40FZW2J8-28B00 | 24 V | 16.0–27.6 V | 5.8 W | 18,000 RPM | 34.7 m³/h | 412.0 Pa | 56.6 dBA |
| J40FZW2K5-28B00 | 24 V | 16.0–27.6 V | 13.3 W | 25,000 RPM | 47.5 m³/h | 750.0 Pa | 63.7 dBA |
| J40FZW3J3-28B00 | 28 V | 18.0–32.0 V | 3.2 W | 13,000 RPM | 26.8 m³/h | 236.5 Pa | 49.5 dBA |
| J40FZW3J8-28B00 | 28 V | 18.0–32.0 V | 5.8 W | 18,000 RPM | 34.7 m³/h | 412.0 Pa | 56.6 dBA |
| J40FZW3K5-28B00 | 28 V | 18.0–32.0 V | 13.3 W | 25,000 RPM | 47.5 m³/h | 750.0 Pa | 63.7 dBA |
Note: Figures are based on the supplied specifications. Confirm the final model, test conditions, and technical documentation with SenharFans before using these values for system design.
Airflow and Static Pressure Performance
The 4028B series provides three nominal performance levels for different cooling requirements.
13,000 RPM: Balanced Performance
The 13,000 RPM configuration has a listed airflow of 26.8 m³/h and static pressure of 236.5 Pa. It may be considered for compact electronic assemblies that require forced-air cooling while operating within a defined power and noise budget.
18,000 RPM: Higher Airflow and Pressure
At 18,000 RPM, the listed airflow increases to 34.7 m³/h, with static pressure reaching 412 Pa. This configuration may suit equipment with greater cooling demands or a more restrictive airflow path, subject to the system’s actual operating point.
25,000 RPM: Maximum Listed Performance
The highest-speed configuration reaches a listed airflow of 47.5 m³/h and static pressure of 750 Pa, with a rated power of 13.3 W.
This option may be relevant to applications with demanding airflow requirements and significant system resistance. However, its listed noise level is 63.7 dBA, which should be carefully evaluated where acoustic limits matter.
Important selection note: Maximum airflow and maximum static pressure are not normally achieved simultaneously. Engineers should use the fan’s airflow-pressure (P-Q) curve to determine the expected operating point in the actual system.
Optional Signal and Control Functions
Depending on the selected configuration, the 4028B DC axial fan can support the following signal and control functions:
- PWM speed control: Enables speed adjustment through a compatible PWM control interface.
- Tachometer feedback (FG): Provides rotational-speed feedback for compatible monitoring systems.
- High-level fault alarm: Provides a fault indication through the specified alarm interface.
- PWM + fault alarm: Combines speed control and fault monitoring.
- PWM + RPM feedback: Combines speed control with rotational-speed monitoring.
These options can help equipment manufacturers integrate fan operation into their control systems and monitor cooling performance.
Signal availability, electrical characteristics, connector pinout, and control requirements should be confirmed for the exact model before integration.
Environmental and Reliability Considerations
Cooling fans used in specialized equipment may need to withstand temperature variations, humidity, vibration, mechanical shock, dust, salt exposure, or electromagnetic interference.
For applications involving defense-related equipment, aerospace systems, vehicle-mounted electronics, or other demanding environments, buyers should identify the applicable environmental and electrical requirements early in the selection process.
Depending on the project, relevant evaluation items may include:
- High- and low-temperature operating requirements
- Humidity and moisture exposure
- Salt spray and corrosion exposure
- Vibration, mechanical shock, and acceleration
- Electromagnetic compatibility (EMC)
- Power supply and electrical interface requirements
The suitability of the 4028B for a particular environment must be verified against the requirements of the application. Request the relevant model-specific test reports and qualification documentation rather than assuming every configuration meets every
environmental standard.
Typical Applications
The 4028B DC axial fan may be considered for the following cooling applications:
- Industrial electronic equipment: Removing heat from compact electronic assemblies.
- Radar and communication equipment: Supporting airflow through appropriately designed electronic enclosures.
- Vehicle-mounted electronics: Providing active cooling where space, power, and thermal requirements must be balanced.
- Specialized control systems: Supporting thermal management in electronic equipment with demanding airflow requirements.
- Other compact systems: Applications where the available installation space is limited and higher static pressure may be needed.
Final suitability depends on the required airflow at the operating pressure, available space, electrical compatibility, acoustic limits, and any applicable environmental qualifications.
How to Choose the Right 4028B Configuration
Before specifying the 4028B for an OEM project, consider the following points:
- Rated voltage: Select the appropriate 12 V, 24 V, or 28 V model and confirm the permitted operating voltage range.
- Required airflow: Determine the airflow needed to remove heat from the target components.
- System resistance: Evaluate pressure losses caused by filters, ducts, vents, grilles, and component layout.
- Noise and power: Compare the performance requirements with the rated power and listed noise level of each configuration.
- Control and monitoring: Confirm whether PWM speed control, tachometer feedback, or a fault alarm is required.
- Environmental conditions: Identify any applicable temperature, humidity, vibration, shock, corrosion, or EMC requirements.
- Technical documentation: Request the relevant performance curves, drawings, electrical specifications, and available test reports.
Providing these details when requesting a quotation helps the supplier evaluate the application and identify a suitable configuration.
Conclusion
The SenharFans 4028B DC Axial Fan combines a compact 40 × 40 × 28 mm form factor with three nominal speed levels and listed static pressure up to 750 Pa. Available in 12 V, 24 V, and 28 V configurations, it offers options for equipment designers evaluating high-performance cooling for compact electronic systems.
The highest-speed version provides the greatest listed airflow and static pressure, but it also has higher power consumption and noise. Selecting the right model therefore requires balancing cooling performance, acoustic requirements, electrical conditions, and system resistance.
Looking for a DC axial fan for your next project?
SenharFans supplies DC axial fans, AC axial fans, DC blower fans, DC condensing fans, centrifugal fans, and integrated motor assemblies for industrial and electronic cooling applications.
Contact our team to discuss your requirements and request model-specific technical information.
Email: sales@senharfans.com
Website: https://senharfans.com/

