Request Custom Quote

4028C DC Axial Fan: Aluminum Alloy Design for Demanding Cooling Applications

SenharFans
4028C DC Axial Fan: Aluminum Alloy Design for Demanding Cooling Applications

4028C DC Axial Fan: Aluminum Alloy Design for Demanding Cooling Applications

Product Overview

The SenharFans 4028C DC Axial Fan is a compact cooling fan designed for electronic systems that require forced-air cooling within limited installation space. Measuring 40.0 × 40.0 × 28.0 mm, the 4028C features an aluminum alloy frame and impeller, dual ball bearings, and multiple voltage and speed configurations.

Available in 12 V, 24 V, and 28 V versions, the series offers nominal speeds of 13,000, 18,000, and 25,000 RPM. These options allow equipment designers to evaluate different combinations of airflow, static pressure, power consumption, and noise.

The 4028C may be considered for industrial electronics, communication equipment, radar-related systems, vehicle-mounted electronics, and other applications requiring compact active cooling. Final suitability depends on the operating conditions and technical requirements of the complete system.

related systems, vehicle-mounted electronics, and other applications requiring compact active cooling. Final suitability depends on the operating conditions and technical requirements of the complete system.

Key Structural Features

  • Dimensions: 40.0 × 40.0 × 28.0 mm
  • Frame material: Aluminum alloy
  • Impeller material: Aluminum alloy
  • Bearing type: Dual ball bearings
  • Weight: Approximately 62.0 g
  • Rated voltage options: 12 V, 24 V, and 28 V
  • Speed options: 13,000, 18,000, and 25,000 RPM
  • Optional control functions: PWM speed control, tachometer feedback, and fault alarm, depending on configuration

The aluminum alloy structure distinguishes the 4028C from plastic-frame and plastic-impeller alternatives in the same nominal size category. Its suitability for a particular installation should be evaluated with the mechanical design, operating environment, and thermal requirements in mind.


4028C DC Axial Fan Specifications

The following table summarizes the supplied performance data for the 4028C series.

Model Rated Voltage Operating Voltage Power Speed Airflow Static Pressure Noise
J40FZW1J3-28C00 12 V 8.0–13.8 V 2.6 W 13,000 RPM 24.4 m³/h 188.5 Pa 48.9 dBA
J40FZW1J8-28C00 12 V 8.0–13.8 V 6.9 W 18,000 RPM 33.8 m³/h 361.3 Pa 56.0 dBA
J40FZW1K5-28C00 12 V 8.0–13.8 V 11.2 W 25,000 RPM 46.9 m³/h 697.0 Pa 63.1 dBA
J40FZW2J3-28C00 24 V 16.0–27.6 V 2.6 W 13,000 RPM 24.4 m³/h 188.5 Pa 48.9 dBA
J40FZW2J8-28C00 24 V 16.0–27.6 V 6.9 W 18,000 RPM 33.8 m³/h 361.3 Pa 56.0 dBA
J40FZW2K5-28C00 24 V 16.0–27.6 V 11.2 W 25,000 RPM 46.9 m³/h 697.0 Pa 63.1 dBA
J40FZW3J3-28C00 28 V 18.0–32.0 V 2.6 W 13,000 RPM 24.4 m³/h 188.5 Pa 48.9 dBA
J40FZW3J8-28C00 28 V 18.0–32.0 V 6.9 W 18,000 RPM 33.8 m³/h 361.3 Pa 56.0 dBA
J40FZW3K5-28C00 28 V 18.0–32.0 V 11.2 W 25,000 RPM 46.9 m³/h 697.0 Pa 63.1 dBA

Note: These values are based on the supplied specifications. Confirm the exact model, measurement conditions, and applicable technical documentation before final design or procurement.

Airflow and Static Pressure Performance

The 4028C series provides three nominal performance levels for different cooling requirements.

13,000 RPM: Compact Cooling Requirements

The 13,000 RPM configuration has a listed airflow of 24.4 m³/h and static pressure of 188.5 Pa. It may be suitable for systems requiring forced-air cooling within a compact enclosure, depending on the resistance of the airflow path.

18,000 RPM: Increased Airflow and Pressure

The 18,000 RPM configuration offers a listed airflow of 33.8 m³/h and static pressure of 361.3 Pa. This option may be considered where the cooling system requires greater airflow or must overcome additional resistance from vents, ducts, filters, or internal components.

25,000 RPM: Higher Cooling Capacity

The highest-speed configuration has a listed airflow of 46.9 m³/h and static pressure of 697 Pa, with rated power of 11.2 W.

This configuration may be relevant to applications with more demanding cooling requirements. However, its listed noise level is 63.1 dBA, so acoustic limits and power availability should be considered during system design.

Important: Maximum airflow and maximum static pressure are not normally achieved simultaneously. Engineers should refer to the fan’s airflow-pressure (P-Q) curve to evaluate the expected operating point in the actual installation.

Signal and Control Options

Depending on the selected configuration, the 4028C DC axial fan can support the following functions:

  • No signal function: For configurations that do not require a signal interface.
  • PWM speed control: Enables speed adjustment through a compatible PWM control interface.
  • Tachometer feedback (FG): Provides rotational-speed feedback for compatible monitoring systems.
  • High-level fault alarm: Provides a fault indication through the specified alarm interface.
  • PWM + fault alarm: Combines speed control with fault monitoring.
  • PWM + RPM feedback: Combines speed control with rotational-speed monitoring.

These options can help equipment manufacturers integrate fan operation into their control and monitoring systems.

Signal availability, connector pinout, electrical characteristics, and control requirements should be confirmed for the exact model before integration.

Environmental and Reliability Considerations

For equipment used in demanding environments, fan selection should consider more than airflow and static pressure. Temperature variations, humidity, salt exposure, mechanical vibration, shock, and electrical interference may all influence the required specification.

For the 4028C, relevant project requirements may include:

  • High- and low-temperature operating conditions
  • Humidity and moisture exposure
  • Salt spray and corrosion exposure
  • Vibration, mechanical shock, and acceleration
  • Electrical interface and power supply requirements
  • Applicable electromagnetic compatibility (EMC) requirements

The original product information references an operating temperature range of −50°C to 85°C. Before publishing this as a general product rating, confirm whether it applies to every 4028C configuration or only to specific models and test conditions.

Environmental performance should be verified using the applicable model-specific specifications and test documentation. An aluminum alloy structure alone does not establish compliance with a particular military, aerospace, or environmental standard.

 


Typical Applications

The 4028C may be considered for cooling applications such as:

  • Industrial electronics: Forced-air cooling for compact electronic assemblies.
  • Radar and communication equipment: Supporting airflow through appropriately designed equipment enclosures.
  • Vehicle-mounted electronics: Cooling systems where installation space, power, and environmental conditions must be considered together.
  • Specialized electronic equipment: Applications requiring a metal-frame and metal-impeller fan configuration.
  • Industrial control systems: Thermal management for electronic equipment operating under defined environmental conditions.

Final suitability depends on the required operating point, installation method, electrical compatibility, noise limits, and any project-specific qualification requirements.

How to Select the Right 4028C Configuration

Before specifying the 4028C for an OEM project, consider the following:

  1. Rated voltage: Choose the appropriate 12 V, 24 V, or 28 V version and verify its permitted operating voltage range.
  2. Airflow and static pressure: Evaluate the required operating point using the P-Q curve and system resistance.
  3. Power consumption: Confirm that the selected configuration fits the available power budget.
  4. Noise limits: Compare the listed noise level with the acoustic requirements of the finished equipment.
  5. Mechanical integration: Check dimensions, mounting arrangements, clearances, and the suitability of the metal structure.
  6. Control functions: Determine whether PWM, tachometer feedback, or a fault alarm is required.
  7. Environmental qualification: Confirm the necessary temperature, humidity, vibration, shock, corrosion, and EMC requirements.
  8. Technical documentation: Request model-specific drawings, performance curves, electrical specifications, and available test reports.

Providing these details when requesting a quotation helps the supplier evaluate the application and identify a suitable configuration.

Conclusion

The SenharFans 4028C DC Axial Fan combines a compact 40 × 40 × 28 mm form factor with an aluminum alloy frame and impeller, dual ball bearings, and multiple speed and voltage options. Its listed performance reaches 46.9 m³/h airflow and 697 Pa static pressure in the highest-speed configuration.

For OEM and equipment manufacturers, selecting the right configuration requires balancing airflow, static pressure, power consumption, noise, mechanical integration, and environmental requirements. Model-specific specifications and test documentation should be reviewed before the fan is adopted for a specialized application.

Looking for a DC axial fan for your next project?

SenharFans supplies DC axial fans, AC axial fans, DC blower fans, DC condensing fans, centrifugal fans, and integrated motor assemblies for industrial and electronic cooling applications.

Contact our team to discuss your requirements and request model-specific technical information.

Email: sales@senharfans.com
Website: https://senharfans.com/

 

Share This Article

Leave a Reply

Your email address will not be published. Required fields are marked *