In compact electronic equipment, cooling performance depends not only on airflow volume but also on the resistance of the air path. Narrow ducts, restricted openings, and densely arranged components can make thermal management more challenging.

The SenharFans 4010A DC Blower Fan is a compact centrifugal blower designed for applications requiring directed airflow within limited installation space. Measuring 40.0 × 40.0 × 10.0 mm, it provides several speed and voltage configurations for equipment designers to evaluate according to their cooling requirements.

Compact Mechanical Design

The 4010A DC Blower Fan combines a compact structure with dual ball bearings.

Key mechanical specifications include:

  • Dimensions: 40.0 × 40.0 × 10.0 mm
  • Frame material: Engineering plastic*
  • Impeller material: Engineering plastic*
  • Bearing structure: Dual ball bearings
  • Weight: 15.0 g

Its compact dimensions make it suitable for equipment where installation space is restricted and airflow needs to be directed through a defined cooling path.


Airflow and Static Pressure Performance

The 4010A series offers three speed configurations across its 12V, 24V, and 28V versions.

Model Voltage Speed Airflow Static Pressure Noise
J40FLW140-10A00 12V 4,000 RPM 1.9 m³/h 17.6 Pa 17.8 dBA
J40FLW160-10A00 12V 6,000 RPM 2.9 m³/h 39.8 Pa 26.7 dBA
J40FLW170-10A00 12V 7,000 RPM 3.4 m³/h 54.2 Pa 30.1 dBA
J40FLW240-10A00 24V 4,000 RPM 1.9 m³/h 17.6 Pa 17.8 dBA
J40FLW260-10A00 24V 6,000 RPM 2.9 m³/h 39.8 Pa 26.7 dBA
J40FLW270-10A00 24V 7,000 RPM 3.4 m³/h 54.2 Pa 30.1 dBA
J40FLW340-10A00 28V 4,000 RPM 1.9 m³/h 17.6 Pa 17.8 dBA
J40FLW360-10A00 28V 6,000 RPM 2.9 m³/h 39.8 Pa 26.7 dBA
J40FLW370-10A00 28V 7,000 RPM 3.4 m³/h 54.2 Pa 30.1 dBA

The listed performance values provide a reference for comparing the available configurations. Actual airflow in an installed system depends on system resistance and the selected operating point on the fan performance curve.

The listed operating voltage ranges are:

  • 12V models: 8.0–13.8V
  • 24V models: 16.0–27.6V
  • 28V models: 18.0–32.0V

Additional 5V and 48V options are listed by SenharFans. Detailed performance data should be requested for these configurations.


Signal and Control Functions

The 4010A supports several optional signal configurations for equipment integration and fan monitoring.

Available options include:

  • No signal function
  • PWM duty-cycle speed control
  • High-level fault alarm
  • Tachometer (RPM) feedback
  • PWM control with high-level fault alarm
  • PWM control with tachometer feedback

The required signal function should be specified when ordering to ensure compatibility with the equipment’s control system.

Environmental Adaptability

The 4010A product specification lists environmental adaptability ratings for two application categories:

Ground / Vehicle-Mounted Applications

The listed environmental tests include:

  • High temperature: 80°C storage / 75°C operation
  • Low temperature: -50°C storage / -40°C operation
  • Rain / water ingress: Enhanced, 1 hour per surface
  • Cyclic humidity: 30°C–60°C, RH 95% ± 5%, 24 hours per cycle, 10 cycles
  • Fungus resistance: Group 1 or Group 2, 28 days
  • Neutral salt spray: 192 hours
  • Blowing sand and dust
  • Acceleration: 9g performance test / 13.5g structural test
  • Shock: 20g

Marine / Naval Applications

The product specification additionally lists acidic salt spray testing for 192 hours.

The referenced test standards include GJB150.3A-2009, GJB150.4A-2009, GJB150.8A-2009, GJB150.9A-2009, GJB150.10A-2009, GJB150.11A-2009, GJB150.12A-2009, GJB150.15A-2009, and GJB150.18A-2009.

The applicable environmental rating should be selected according to the intended installation environment and the required product configuration. Refer to the technical documentation for the full test conditions.


Typical Applications

The compact 4010A DC blower format may be considered for:

  • Communication equipment
  • Industrial control electronics
  • Compact power modules
  • Electronic enclosures with restricted airflow paths
  • Vehicle-mounted electronic equipment
  • Marine electronic equipment, subject to the required environmental rating

Final selection should consider the available installation space, thermal load, airflow path, electrical supply, and environmental requirements.

Request Technical Information

SenharFans provides DC blower fan configurations for equipment manufacturers, OEM customers, and system integrators.

If you are evaluating the 4010A DC Blower Fan for your project, please share your required voltage, airflow and pressure targets, installation dimensions, and environmental conditions.

Our team can help you review the available configurations and technical information.

Contact SenharFans

Email: sales@senharfans.com

Website: https://senharfans.com/

Phone / WhatsApp: +86-138-1239-0890

performance cannot be compromised.

Share This Article

Leave a Reply

Your email address will not be published. Required fields are marked *