5010A DC Blower Fan – Compact Cooling for Space-Constrained Systems
In compact electronic equipment, airflow must often pass through restricted spaces, narrow ducts, and densely arranged components. These conditions make static pressure an important factor when selecting a cooling fan.
The SenharFans 5010A DC Blower Fan is a compact centrifugal blower designed for equipment that requires directed airflow within limited installation space.
Measuring 52.4 × 41.0 × 10.5 mm, the 5010A features an engineering plastic frame and impeller, dual ball bearings, and multiple voltage and speed configurations.
Compact Mechanical Design
The 5010A DC Blower Fan is designed for compact equipment assemblies where installation dimensions and airflow direction are important considerations.
Key mechanical specifications:
- Dimensions: 52.4 × 41.0 × 10.5 mm
- Frame material: Engineering plastic
- Impeller material: Engineering plastic
- Bearing structure: Dual ball bearings
- Weight: 21.0 g
Its compact form factor allows integration into equipment with limited internal space and defined airflow paths.

Airflow and Static Pressure Performance
The 5010A series is available in 12V, 24V, and 28V configurations, with two speed options for each voltage.
The detailed performance specifications are listed below:
| Model | Voltage | Operating Voltage | Power | Speed | Airflow | Static Pressure | Noise |
|---|---|---|---|---|---|---|---|
| J50FLW155-10A00 | 12V | 8.0–13.8V | 1.0W | 5,500 RPM | 5.6 m³/h | 84.3 Pa | 35.4 dBA |
| J50FLW165-10A00 | 12V | 8.0–13.8V | 2.23W | 6,500 RPM | 6.6 m³/h | 117.7 Pa | 39.0 dBA |
| J50FLW255-10A00 | 24V | 16.0–27.6V | 1.0W | 5,500 RPM | 5.6 m³/h | 84.3 Pa | 35.4 dBA |
| J50FLW265-10A00 | 24V | 16.0–27.6V | 2.23W | 6,500 RPM | 6.6 m³/h | 117.7 Pa | 39.0 dBA |
| J50FLW355-10A00 | 28V | 18.0–32.0V | 1.0W | 5,500 RPM | 5.6 m³/h | 84.3 Pa | 35.4 dBA |
| J50FLW365-10A00 | 28V | 18.0–32.0V | 2.23W | 6,500 RPM | 6.6 m³/h | 117.7 Pa | 39.0 dBA |
Additional 5V and 48V options are listed for the series. Detailed performance specifications for these voltage configurations should be confirmed separately.
The airflow and static pressure values represent specified performance data for the listed configurations. Actual airflow in an installed system depends on system resistance and the operating point on the fan performance curve.
Engineers should consider the complete airflow path, including ducts, vents, filters, and heat sinks, when selecting a suitable configuration.
Signal and Control Options
The 5010A supports different signal functions for speed control and operating-status monitoring.
Available signal configurations include:
- No signal function
- PWM duty-cycle speed control
- High-level fault alarm
- Tachometer (RPM) feedback
- PWM control with high-level fault alarm
- PWM control with tachometer feedback
The required signal function should be specified during product selection to ensure compatibility with the equipment’s control system.
Environmental Adaptability
The 5010A product specification provides environmental adaptability ratings for different application categories.
The listed categories include:
- Ground / Vehicle-Mounted Applications
- Marine / Naval Applications
- Airborne Applications
The environmental table references the following test standards and conditions:
Temperature
- GJB150.3A-2009 – High Temperature
- GJB150.4A-2009 – Low Temperature
The table lists 80°C storage / 75°C operation for the ground or vehicle-mounted category, and 95°C storage / 85°C operation for the marine category. Low-temperature values are -50°C storage / -40°C operation and -60°C storage / -55°C operation, respectively.
Other Environmental Tests
- GJB150.8A-2009 – Rain
- GJB150.9A-2009 – Damp Heat
- GJB150.10A-2009 – Fungus
- GJB150.11A-2009 – Salt Spray
- GJB150.12A-2009 – Sand and Dust
- GJB150.15A-2009 – Acceleration
- GJB150.18A-2009 – Shock
- GJB150.2A-2009 – Low Air Pressure
- GJB150.28A-2009 – Acidic Atmosphere
The table specifies neutral salt spray for 192 hours in the ground / vehicle-mounted category and acidic salt spray for 192 hours in the marine / naval category. It also lists a 6.3 kPa low-air-pressure condition and an acidic-atmosphere cycle for the airborne category.
These ratings are category-specific. Not every test or condition applies to every configuration. Please consult the product’s detailed environmental adaptability table and technical documentation when selecting a version for a particular application.

Typical Applications
The 5010A DC Blower Fan may be considered for:
- Power electronics and inverter cooling
- Compact electronic enclosures
- Communication equipment
- Industrial control equipment
- Vehicle-mounted electronic systems
- Equipment requiring directed airflow through restricted cooling paths
Final selection should consider installation dimensions, thermal load, required airflow and pressure, electrical supply, signal functions, and environmental conditions.
Request Technical Information
SenharFans provides DC blower fan configurations for OEM customers, equipment manufacturers, and system integrators.
When requesting information about the 5010A DC Blower Fan, please share your required voltage, target airflow and static pressure, installation dimensions, control functions, and intended operating environment.
Our team can help review the available configurations and provide relevant technical information for your project.
Contact SenharFans
Email: sales@senharfans.com
Website: https://senharfans.com/
Phone / WhatsApp: +86-138-1239-0890