4015A DC Axial Fan: Compact Cooling for Demanding Electronic Systems
Compact Design with Flexible Cooling Performance
The 4015A DC Axial Fan is a compact cooling fan designed for electronic equipment and industrial systems where installation space, airflow, and environmental requirements must be considered together.
With a 40 × 40 × 15 mm form factor, engineering-plastic frame and impeller, and dual ball bearings, the 4015A series offers multiple performance and control configurations for different cooling requirements. Depending on the selected model, engineers can choose suitable operating parameters and optional monitoring functions to support system integration.
Key Design Features
- Compact dimensions: 40 × 40 × 15 mm, suitable for space-constrained equipment.
- Frame and impeller: Engineering plastic.
- Bearing system: Dual ball bearings.
- Weight: Approximately 25 g, according to the supplied product information.
- Configuration flexibility: Multiple voltage, speed, and signal-function options, depending on the selected model.
These features make the 4015A a candidate for electronic assemblies that require forced-air cooling within a compact installation space.
Performance Options and Airflow Characteristics
The 4015A series offers different performance configurations to accommodate varying airflow and system-resistance requirements.
| Parameter | Available specification |
|---|---|
| Dimensions | 40 × 40 × 15 mm |
| Voltage options | 5 V / 12 V / 24 V / 28 V / 48 V, subject to model availability |
| Speed range | 6,000–12,000 RPM |
| Maximum airflow | Up to 24.0 m³/h |
| Maximum static pressure | Up to 168 Pa |
| Bearing type | Dual ball bearings |
Actual performance depends on the selected model and operating conditions. Maximum airflow and maximum static pressure are separate performance limits and should not be assumed to occur simultaneously.
For accurate selection, engineers should review the relevant airflow–static pressure (P–Q) curve and compare the fan’s operating point with the resistance of the complete cooling system. Airflow restrictions caused by filters, grilles, ducts, and closely spaced components can affect the airflow delivered in the final installation.
Refer to the 4015A DC Axial Flow Fan product page for product drawings and available performance information.
Signal and Speed-Control Options
Different equipment designs require different levels of fan monitoring and control. Depending on the selected configuration, the 4015A series can offer the following options:
- No signal function: For applications that do not require additional monitoring signals.
- PWM speed control: Allows the system controller to adjust fan speed through a supported PWM input.
- High-level fault alarm: Provides a fault-indication output according to the specified electrical interface.
- Tachometer (FG) feedback: Provides a signal for monitoring fan rotation speed.
- PWM + fault alarm: Combines speed control with fault monitoring.
- PWM + FG feedback: Combines speed control with rotation-speed feedback.
Signal availability, wiring, electrical characteristics, and control compatibility should be confirmed for the exact model before system integration.
Environmental Requirements and Model Selection
For equipment operating in demanding environments, fan selection involves more than airflow and dimensions. Temperature, humidity, water exposure, salt spray, dust, vibration, shock, and electromagnetic compatibility may all affect the suitability of a fan for a particular installation.
The 4015A series may be available with different environmental adaptations or test options, depending on the model and project requirements. Relevant considerations may include:
- High- and low-temperature operation
- Damp heat and humidity exposure
- Rain or water-ingress protection
- Salt spray and fungal exposure
- Sand and dust exposure
- Shock, vibration, and acceleration
- Electromagnetic compatibility and power-supply requirements
Where GJB standards or other military environmental requirements apply, the exact standard, test method, severity level, and applicable fan configuration should be confirmed against the relevant technical documentation. Environmental test results for one configuration should not automatically be applied to every version of the series.
For vehicle-mounted, marine, radar, communication, or other specialized equipment, engineers should specify the actual operating environment and required qualification conditions before confirming a fan model.
Typical Applications
Subject to the selected model’s specifications and environmental suitability, the 4015A DC axial fan may be considered for:
- Electronic equipment and compact cooling modules
- Radar and communication equipment
- Industrial control cabinets
- Power supplies and electronic assemblies
- Vehicle-mounted electronic systems
- Specialized equipment requiring compact forced-air cooling
Final suitability depends on the system’s thermal load, airflow path, available installation space, electrical interface, and environmental requirements.

How to Select the Right 4015A Configuration
Before requesting a quotation, engineers can prepare the following information:
- Electrical requirements: Rated voltage and allowable operating-voltage range.
- Cooling requirements: Required airflow, system resistance, and thermal load.
- Installation constraints: Available dimensions, mounting arrangement, and airflow direction.
- Control and monitoring: Whether PWM control, FG speed feedback, or a fault-alarm output is required.
- Environmental conditions: Operating temperature, humidity, dust, water exposure, vibration, and applicable test standards.
- Documentation: Required drawings, performance curves, test reports, and qualification documents.
Providing these details helps SenharFans assess which configuration is most appropriate for the application.
Contact SenharFans
The 4015A DC Axial Fan offers a compact 40 mm design and multiple performance and signal options for electronic and industrial cooling applications.
For detailed dimensions, model-specific performance curves, electrical specifications, or environmental documentation, visit the 4015A product page or contact SenharFans at sales@senharfans.com.
Our team can help review your application requirements and identify a suitable configuration.

